IHY-50KH3-G1 50kW Hybrid Inverter Storage System
Industrial-Grade 50kW 3-Phase Intelligent Hybrid Inverter combined with Tier-1 16kWh High-Capacity Energy Storage.
Uncompromising Commercial Power Control
Take charge of your enterprise or luxury estate’s power dynamics with the ultimate energy infrastructure solution. The itel Energy 50kW Hybrid Inverter combined with the high-density 16kWh IPX-51314SPT Lithium-Iron Phosphate Battery platform sets a new benchmark in efficiency, uptime protection, and economic utility. Boasting an extraordinary 99.90% MPPT tracking efficiency, a 160% DC solar array oversizing capability, and true 100% unbalanced phase output management, this system stops your reliance on the volatile grid and eliminates peak electricity costs.
⚡ 100% Unbalanced Output
Unlike standard 3-phase systems, this inverter routes power directly to whichever phase experiences the highest demand, boosting self-consumption and preventing costly grid pull.
🔋 Rapid 150A Energy Flux
Massive 150A charging and discharging capacity speeds up energy storage transfers into the high-voltage LiFePO4 cells when solar yields peak.
🌤️ Ultra-Dense 4-MPPT Array
Four independent MPPT trackers carrying dual strings each give your project extreme layout flexibility across varying roof angles and shading landscapes.
Real-World Operational Scenarios
Scenario 1: Peak-Shaving & TOU Strategy for Commercial Facilities
The Challenge: High Demand Charges during peak mid-afternoon hours when industrial equipment or cooling units operate at max capacity.
The Solution: The system leverages the Intelligent EMS platform with Six Work Modes. It charges the IPX-51314SPT batteries at low-rate hours and discharges the stored 50kW during high-tier pricing periods, dramatically flattening grid expenditure.
Scenario 2: True Off-Grid Resilience with Diesel Generator Interlocking
The Challenge: Extended multi-day power outages in remote agricultural or mining sites during overcast weather.
The Solution: When solar yields drop and the high-voltage battery bank depletes to safety thresholds, the inverter uses integrated dry contact support to automatically ignite a backup Diesel Generator. The system seamlessly routes power to critical smart loads while simultaneously recharging the battery cells at a rapid 150A.
Scenario 3: Uninterrupted Phase Protection for Critical Labs & Server Infrastructure
The Challenge: Grid dropouts damaging highly sensitive single-phase or multi-phase equipment.
The Solution: Offering an instantaneous millisecond-level transfer switch window and 150% maximum backup surge allowance for 10 full seconds, the system confidently stabilizes high-inrush startup loads without dropping data or losing machinery uptime.
Technical Specifications
Inverter Parameters (IHY-50KH3S)
| Max. PV Input Power | 75,000 W |
|---|---|
| Max. DC Input Voltage | 1,000 V |
| MPPT Voltage Range | 700 V – 950 V |
| Number of MPPTs (Strings) | 4 MPPTs (2 per MPPT) |
| Normal AC Output Power | 50,000 W |
| Nominal Grid Voltage | 220/380V, 230/400V (3L-NPE) |
| Max Surge Power Allowance | 75,000 VA (110% continuous, 150% @ 10s) |
| Battery Voltage Windows | 160 V – 840 V |
| Ingress Protection Rating | IP66 |
Battery Module Parameters (IPX-51314SPT)
| Chemistry Type | Class-A LiFePO4 (Lithium-Iron Phosphate) |
|---|---|
| Module Nominal Energy | 16 kWh |
| Module Nominal Voltage / Cap | 51.2 V / 314 Ah |
| Operating Voltage Range | 48 V – 56 V |
| Continuous Charge/Discharge | 200 A |
| Lifespan Cycle Performance | ≥ 6,000 Cycles @ 25°C (80% DOD) |
| BMS Safety Protection | 50+ Protections (3-Level Hardware Linkage) |
| Scalability Potential | Up to 16 in Parallel & 12 in Series |
| Recommended Assembly Example | 12S1P Stack (614.4V Nominal | 192kWh Energy) |
Frequently Asked Questions
Can I operate the 50kW Hybrid Inverter without buying the batteries?
The inverter can technically feed power back into the grid like a traditional grid-tied inverter if net-metering rules permit. However, to execute backup protection, time-of-use load shifting, generator control, and complete blackout defense, you must integrate the matching IPX-51314SPT battery storage modules.
Why is the inverter battery voltage rated up to 840V while a single battery module is 51.2V?
This is a high-voltage, high-efficiency architecture. The IPX-51314SPT batteries are designed to connect in series inside a high-voltage battery cabinet. For instance, connecting 12 battery packs in a series configuration yields a system nominal voltage of 614.4V with 192kWh of stored energy, putting it squarely in the inverter’s sweet spot for low-loss power conversions.
What happens if my building draws a heavy inductive load like a major motor?
The inverter boasts a 150% maximum backup power overload envelope, handling transient surge demands up to 75,000 VA for up to 10 seconds without experiencing system trips or thermal dropouts.
Can I update or manage the system safely from afar?
Yes. The platform includes an advanced EMS portal with built-in Bluetooth tracking for immediate commissioning alongside options for Wi-Fi, LAN, or CAN networks to handle remote firmware upgrades and real-time operational fine-tuning.











Reviews
There are no reviews yet.